Moxa Technologies EDS-405A User Manual

Page of 82
EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-48
2.  Activate your settings 
After configuring, you will need to activate your EDS’s Relay Event Types. 
Relay Warning Events Settings 
 
NOTE: The user interface for the EDS-408A shows 8 ports. 
Event Types 
Event Types can be divided into two basic groups: System Events and Port Events. System 
Events are related to the overall function of the switch, whereas Port Events are related to the 
activity of a specific port. 
The EDS supports one relay output. You can configure which relay output is related to which 
events. This helps administrators identify the importance of the different events. 
System Event 
Warning Relay output is triggered when… 
Power Transition (OnÆOff) 
EDS is powered up. 
Power Transition (OffÆOn) 
EDS is powered down. 
Turbo Ring Break (Ring Master 
Only) 
When the EDS-408A/405A is the 
Master of this Turbo Ring, and the 
Turbo Ring is disconnected. 
 
 
NOTE 
If the Turbo Ring Switch function is enabled, and the Turbo Ring DIP Switch is set to “ON”, the 
Turbo Ring Break Event cannot be changed. If not, the Turbo Ring Break Event can be set by 
using a web browser. 
 
NOTE 
The Turbo Ring Break Warning will be automatically enabled when the following configuration 
is set: 
1.  Turbo Ring DIP Switch functions are enabled. 
2.  The Hardware Turbo Ring DIP Switch is set to “ON”. 
3.  The Master DIP Switch is set to “ON”. 
Please refer to “Configuring Basic Settings—Turbo Ring DIP Switch” for more details.