Port Event 
Warning e-mail is sent when… 
Link-on 
The port is connected to another device. 
Link-off 
The port is disconnected (e.g., the cable is pulled 
out, or the opposing device shuts down). 
Traffic-Overload 
The port’s traffic surpasses the Traffic-Threshold for 
that port (provided this setting is Enabled). 
Traffic-Threshold (%) 
Enter a nonzero number if the port’s 
Traffic-Overload setting is Enabled. 
Traffic-Duration (sec.) 
A Traffic-Overload warning is sent every 
Traffic-Duration seconds if the average 
Traffic-Threshold is surpassed during that time 
period. 
 
NOTE 
The Traffic-OverloadTraffic-Threshold (%), and Traffic-Duration (sec.) Port Event settings 
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero 
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds. 
 
NOTE 
Warning e-mail messages will have the sender field in the form: 
Moxa_EtherDevice_Switch_0001@Switch_Location 
where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is EDS’s serial number, and 
Switch_Location is the default Server Location. 
Refer to the Basic Settings section to see how to modify Switch Name and Switch Location. 