44
Options Guide    
 
 
Installing the RemoteView Service Board S2 LP RemoteView Components
Figure 24: Installing the RSB S2 LP
Ê
Remove the slot cover.
I
Keep the slot cover for future use. If you remove the RSB S2 without 
installing a new one, you must reinstall the slot cover to comply with 
EMC regulations (regulations on electromagnetic compatibility) and 
to satisfy cooling requirements and fire protection measures.
Ê
Install the RSB S2 LP in the low-profile PCI slot (#2) of the riser card. The 
procedure is described in the section “Installing controllers” on page 40.
Ê
Plug the power cable into the CN7 connector of the system board. 
I
The position of the connectors is described in the “Technical Manual 
of the System Board D1790”.
Ê
Plug the data cable into the CN6 socket (IPMB) of the system board.
Ê
Install the riser card holder (see page 41).
Ê
Close the server, plug in the power plugs, and switch on the server as 
described in the chapter “Completion” on page 45f.