Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r 
4-8
Remove the Present System 
4
Disable TTI
!
CAUTION:
If you do not disable the TTI, the translations can be corrupted.
1. Make sure the ISDN is in service. If not, attempt to busy out and release 
the ISDN D-channel/link. This will bring the ISDN trunks back into service.
2. Type change system-parameters features and press 
Enter.
 
3. On the second screen, set the 
Enabled?
 field to n to de-activate the TTI 
feature.
Disable Alarm Origination to INADS
1. Type change system-parameters maintenance and press 
Enter
2. Type neither in the 
Alarm Origination to OSS Numbers 
field.
3. For some releases of software, disable 
Cleared Alarm Notification 
and 
Restart Notification
 field before submitting the form.
!
CAUTION:
If Alarm Origination is not disabled, the system may generate alarms, 
resulting in unnecessary trouble tickets.
Shut Down DEFINITY LAN Gateway System
!
WARNING:
Neglecting to shut down a DEFINITY LAN Gateway assembly before 
powering down the system cabinet can damage the LAN Gateway disk.
1. Log onto the DEFINITY LAN Gateway. See 
DEFINITY Communications 
System Generic 3 Installation, Administration and Maintenance of 
CallVisor ASAI over the DEFINITY LAN Gateway for the procedure to log 
on.
2. When the main menu appears, select 
Maintenance.
3. Select 
Reset System from the Maintenance menu.
4. Select 
Shutdown from the Reset System menu.
5. Unseat the LAN Gateway assembly from its backplane connectors.