Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
G3vs with Intel 386 or Risc Processor to R8r 
4-10
Remove the Present System 
4
Disconnect Power and Ground
1. Disconnect the cabinet power cords from the rear of the cabinet.
2. Disconnect the 10 AWG (#25) (2.6 mm
2
) coupled bonding conductor wire.
3. Disconnect the 6 AWG (#40) (4.1 mm
2
) CABINET GROUND wire from the 
ground bar in the cabinet.
Remove the Present System
1. Disconnect the management terminal from the TERM connector.
2. Remove all of the 25-pair cables from the rear of the system. Retain any 
cables that can be reused with the Release 8r cabinet.
3. Remove the AC power cord from the system.
4. Remove the ground wires from the system. If the wires can reach the 
Release 8r cabinet, retain them for connection to the Release 8r system.