Multicarrier G2 Universal Module to R8r EPN 
5-112
Critical Reliability 
5
Resolve Alarms
Examine the alarm log. Resolve any alarms that may exist using 
DEFINITY 
Enterprise Communications Server Release 8 Maintenance for R8si or DEFINITY 
Enterprise Communications Server Release 8 Maintenance for R8r. 
Enable Customer Options and Alarm Origination
1. Get the DOSS order number of the upgrade from the project manager and 
ask the regional Customer Software Administration to complete the steps 
in the shaded box. See 
 
for telephone numbers.
NOTE:
As part of the system registration process, the INADS Database 
Administrator enables Alarm Origination.
2. When administration is completed, log in as craft at the 
Login:
 prompt.
"init" login administration:
1. Log in as init.
2. Type change system-parameters customer-options and press 
Enter 
to verify that the customer options are properly set.
3. Go to screen 6, QSIG Optional Features, and set the 
Basic Call 
Setup 
field to y if the customer was using Supplementary Services 
Protocol b or d on an ISDN-PRI trunk group before the upgrade.
4. Type change system-parameters offer-options and press 
Enter
.
5. If the 
Activate Offer
 field is n, set it to y and press 
Tab
. A warning 
message lets you know whether you need to save translations and 
reboot to make the change permanent.
6. Press 
Enter
 to effect the changes or 
Cancel
 if there were no changes.
7. Contact the requester when done.