Lucent Technologies 555-233-115 User Manual

Page of 502
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-78
Add IP Interface Assembly 
6
Circuit Pack Verification
1. Type change circuit-pack and press 
Enter
.
2. Check the Code column to see if it says DSMAPD or MedPro.
.
3. To correct it, go to the entry just above the TN802B that says DSMAPD.
4. Type MEDPRO, and press 
Enter
. Changing the one entry automatically 
changes the entry above it. If it is in IP Trunk mode, you get the following 
error message:
MedPro type requires TN802 with application. Type 
MEDPRO on circuit-packs form.
5. To complete the administration, refer to the 
DEFINITY ECS Release 8 
Network Connectivity book.
change circuit-packs                                            Page   1 of   5 
                              CIRCUIT PACKS                                     
        Cabinet: 1                            Carrier: A
                                         Carrier Type: processor        
 Slot Code  Sf Mode   Name               Slot Code  Sf Mode   Name
11:
MEDPRO RESERVED-IP
01: TN754 
DIGITAL LINE 
12:
MEDPRO 
RESERVED-IP
02: TN758 
POOLED MODEM 
13:
TN802  B 
MAPD BOARD
03: TN2144 
ANALOG LINE 
14: 
04: TN746  B 
ANALOG LINE 
15: 
05
16:         
06: TN771  C 
MAINTENANCE/TEST  
07: TN464  F 
DS1 INTERFACE     
08: TN2140 
E&M TIE TRUNK     
09: TN767  E 
DS1 INTERFACE     
10: TN799  B 
CONTROL-LAN       
  ’#’ indicates circuit pack conflict.