DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r  
555-233-115  
Issue 1
April 2000
Adding or Removing Cabinet Hardware 
6-79
Add TTC Japanese 2Mbit Trunks 
6
Add TTC Japanese 2Mbit Trunks
The TN2242 Japan 2Mbit trunk interconnects DEFINITY with other vendor 
equipment in Japan as well as to interconnect other DEFINITY switches through 
the Time Division Multiplexor device.
Installation
1. Determine the port assignment of the trunk from the Trunk Group screen.
2. Install a TN2242 circuit pack in assigned carrier slot.
3. Connect the H600-513 cable from the DEFINITY cabinet to the Time 
Division Multiplexor device.
4. To administer forms, see the following sections in the 
DEFINITY Enterprise 
Communications Server Release 8 Administrator’s Guide.
For ISDN applications, see the “ISDN Service” section.
For non-ISDN applications, see the “Managing Trunks” section.
EXAMPLE:
1
A
07
01
Cabinet (Port 
Network)
Carrier
Slot 
Number
Port 
Number