Grindmaster PBIC-430V2E230 User Manual

Page of 44
Shuttle Brewers & Airpot/Shuttle Brewers
Page 19
Factory/Field Test Menu (cont.)
Step
Function
Operation
Description
1
LED Test
All LEDs ON
Verify that all LEDs turn on.
2
Firmware Version
Display firmware version
Shows the software version of the control.
3
Date Code
Not used
Not used
4
EEPROM Version 
Not used
Not used
5
Non Resetable Unit
Counter
Scroll non-resetable unit counter
Shows the total number of brews made by
the brewer (both sides if a double unit)
6
Display Water
Temperature
Show averaged A/D reading of temperature Shows the current temperature in °F of the
thermister.
7
Display Water Level 1
Show averaged A/D reading of water level 1 If > 500 water level is full,
If < 500 water level is not full.
8
Display Water Level 2
Show averaged A/D reading of water level 2 If > 500 water is at the heater level, 
If < 500 water level not at the heater level.
9
Show Input
Display scrolls “InPut
Input Test Mode
10
Input Test
Press each key and the display will show a
number related to that key
Right Side
On/Off - 1 (advances test)
Up - 5
Down - 3
Large Brew - 4
Medium Brew - 2
Small Brew - 0
Basket Switch - 17
Left Side
On/Off - 9
Up - 13
Down - 11
Large Brew - 12
Medium Brew - 10
Small Brew - 8
Basket Switch - 16
11
Show Output
Display scrolls “outPut
Output Test Mode
12
Output Test
Turns on each relay separately. Displays
“O##“ where:
## = 2 digit output number
IMPORTANT: Each output will be turned
ON when its number is on the display
REGARDLESS of temperature or fill
level. Be CAREFUL not to overfill the
tank and keep electric items out of the
way of the brew channel.
Scroll through relay outputs with the UP
and DOWN keys.
Outputs are as follows:
O01 - Fill Valve
O02 - Right Bypass Valve
O03 - Left Bypass Valve
O04 - Right Brew Valve
O05 - Left Brew Valve
O06 - not used
O07 - Tank Heater
O08 - Right Basket Lock
O09 - Left Basket Lock
O10 - not used