Installation Completion and Cable Pinouts 
Page 2-4
Installation Completion 
2
Installation Completion
1. Enter logoff and press 
Enter 
to prevent unauthorized changes to data. 
2. Set the left and right doors onto the hinge pins and close the doors. The 
doors must be closed to prevent EMI emissions. Tighten the door screws. 
3. Set the right cover panel onto the right panel and secure. Do not use 
force.
Power Supply LED Indications
It is not possible to view the alarm log to determine which power unit in a 
multi-cabinet system is defective. Use the LEDs on the front of each power unit to 
determine its state. 
Table 2-1
 shows the LED and alarm conditions. Ring voltage and neon bus 
output do not activate alarm status. 
Table 2-1.
LED and Alarm Conditions
Condition
LED Status
Alarm State
Fan Alarm
Normal
Red off 
Yellow on
open
high
No Input Power
Red off 
Yellow off
closed
open
Any DC Output 
not Present
Red on 
Yellow off
closed
no state
Fan Alarm
Red on 
Yellow off
closed
low