PLUMBING REQUIREMENTS
This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi (138 and 620 
kPa) from a 
1
2
" or larger supply line.  A shut-off valve should be installed in the line before the brewer.  Install a regulator 
in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa).  The water inlet fitting is 
3
8
" flare  
or female quick connect.
NOTE – Bunn-O-Matic recommends 
3
8
" copper tubing for all installations from the 
1
2
" water supply line.  A tight coil of 
copper tubing in the water line will facilitate moving the brewer to clean the counter top.  Bunn-O-Matic does not recom-
mend the use of a saddle valve to install the brewer.  The size and shape of the hole made in the supply line by this type 
of device may restrict water flow.
This equipment must be installed to comply with the Basic Plumbing Code of the Building Officials and 
Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and 
Drug Administration (FDA). For models installed outside the U.S., you must comply with the applicable 
Plumbing/Sanitation Code for your area.
PLUMBING HOOK-UP
1.  Flush the water line and securely attach it to the flare fitting located on bottom of brewer.
2.  Turn on the water supply.
35879.1 110507
CE REQUIREMENTS
• This appliance must be installed in locations where it can be overseen by trained personnel.
• For proper operation, this appliance must be installed where the temperature is between 0°C to 35°C.
• Appliance shall not be tilted more than 10° for safe operation.
• An electrician must provide electrical service as specified in conformance with all local and national codes
• This appliance must not be cleaned by water jet
• This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given instructions concerning
use of this appliance by a person responsible for its safety.