3.6.12  unprovisionEquipment 
Synopsis 
Description 
This interface enables the NMS to permanently unprovision equipment from the managed element. The 
successful result of this operation is the potential deletion of the equipment object and all of its related 
objects, such as termination points. 
The ONS 15454 SONET and, ONS NCS2000 SONET does not allow a user to unprovision a piece of 
equipment that is in use (SNC is created on this equipment). However, if the equipment is present in the 
slot and is not in use, it can be unprovisioned. If the equipment is not physically removed from the slot 
and new equipment is not provisioned in the same slot, the NE redetects the equipment in approximately 
1 minute. If the equipment is not physically removed from the slot and new equipment of a different type 
is provisioned in the same slot, the NE generates an equipment mismatch alarm. 
If the equipment is unprovisioned successfully, Prime Optical generates a state change event on the holder 
state change and an object deletion event for the equipment, and pushes them to the event channel. 
The ONS 15454 reserves slots 7 and 11 for TCC. One of these slots has an in-service TCC card. If the 
NMS invokes unprovisionEquipment on this equipment, Prime Optical throws the 
EXCPT_UNABLE_TO_COMPLY exception. 
In case of NCS 2000 SONET and NCS 2000 SDH, when unprovisionEquipment is invoked on slot 18 of 
M15 chassis on ECU equipment, Prime optical throws the EXCPT_UNABLE_TO_COMPLY exception. 
 
Parameters 
 
Name 
Type 
Input/Output 
Description 
equipmentName 
globaldefs::NamingAttributes_T  In 
Name of the 
equipment to 
unprovision. 
 
This interface is not applicable for configuring payloads for client ports in TXP_MR_10G.  
Throws 
Compliance 
TMF-defined.