Electrical Requirements
M414038
46
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
For CE Marked Models Only
All manually operated models are factory-equipped 
with an emergency stop button on the front panel.
NOTE: Activation of the emergency stop switch 
stops all machine control circuit functions, but 
DOES NOT remove all electrical power from 
machine.
To Connect Electrical Service to the 
Tumbler
NOTE: The wiring diagram is supplied in 
literature packet in cylinder.
1. Install a circuit breaker as close to the tumbler as 
possible. If more than one tumbler is being 
installed, a disconnect switch or circuit breaker 
should be provided for each. This will make it 
possible to disconnect each tumbler for 
maintenance purposes.
2. Connect conduit-encased leads to the disconnect 
switch or circuit breaker. Connect wire leads to 
the appropriate labeled terminal on the terminal 
block. The ground wire must be connected to the 
ground connection as shown in Figure 18
3. Check the electrical service phase sequence 
(three phase only) as follows:
a. If one of the power leads is a “high leg,” 
connect it to lead L3 in the tumbler. The 
cylinder must rotate clockwise and the fan 
must rotate counterclockwise (as viewed from 
the front of the tumbler – with selector switch 
in non-reverse position). If not, interchange 
leads L1 and L2 in the tumbler connection 
box. 
NOTE: On reversing tumblers, the fan motor 
rotates counterclockwise (viewed from the front).
b. Disconnect and reverse any two leads at 
connections.
Figure 18 
T390I
1
Contactor Box or Junction Box
2
Electrical Service
3
Fuses
4
Ground Screw
TMB1275N
T390i
1
2
3
4
NON-CE MARKED MODELS
TMB1275N
CE MARKED MODELS
1
2
3
3