Alliance Laundry Systems SWD439C User Manual

Page of 76
Installation
800937
30
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Location Requirements
Select a location with a solid floor.
The unit must not be installed or stored in an area 
where it will be exposed to water and/or weather.
Leveling legs can be adjusted from inside the unit with 
a 7/8 in. deep well socket. All four legs must rest 
firmly on the floor so the weight of the unit is evenly 
distributed. The unit must not rock and must be level 
from side-to-side and front-to-back.
IMPORTANT: Unless completely assembled, DO 
NOT slide the unit across the floor. DO NOT slide 
the unit more than four feet once the leveling legs 
have been extended, as the legs and the base could 
become damaged.
The unit needs sufficient clearance and an adequate air 
supply for proper operation and ventilation, and for 
easier installation and servicing. (Minimum clearances 
are shown in Figure 41.
Figure 41 
NOTE: Shaded areas indicate adjacent structure.
SWD453N
SWD453N
A
B
C
D
E
E
Dryer and Exhaust Duct Clearances
Area
Description
Minimum Clearance
A
Left Dryer Side
0" (0 cm)
B
Right Dryer Side
0" (0 cm)
C
Dryer Top
6" (15.24 cm)
D
Dryer Rear
2" (5.1 cm)
E
Exhaust Duct Clearance to Combustible Materials
2" (5.1 cm)