Siemens stober combidrive cm150-3 User Manual

Page of 40
2.  Installation
English
© STÖBER plc 1997
5
05.02.01
CombiDrive
®
 – Dimension 
(Only dimensions of the motor, total dimensions of the gear motor see
MGS-catalog, Impr.-No. 440 637)
qx =  Max. dimension; Given either through the inverter or through the fan cowl.
Motor-type
Motor
output rating
Inverter type
Width (b)
Dimension
qx
71 K
0,25 kW
PM 25/1
122
182
237
71 L
0,37 kW
PM 37/1
122
182
237
80 K
0,55 kW
PM 55/1
122
193
259,5
sin
g
le-
p
h
ase
80 L
0,75 kW
PM 75/1
122
193
259,5
Motor-type
Motor
output rating
Inverter type
Width (b)
Dimension
qx
71 L
0,37 kW
PM 37/3
122
182
237
80 K
0,55 kW
PM 55/3
122
193
259,5
80 L
0,75 kW
PM 75/3
122
193
259,5
90 K
1,1 kW
PM 110/3
171
201
296
90 L
1,5 kW
PM 150/3
171
201
296
100 K
2,2 kW
PM 220/3
171
234
328,5
100 L
3,0 kW
PM 300/3
171
234
328,5
112 K
4,0 kW
PM 400/3
171
248,5
353
132 K
5,5 kW
PM 550/3
171
264,5
372,5
th
ree-
p
h
ase
132 L
7,5 kW
PM 750/3
171
264,5
372,5
Dimension in mm
Installation notes
The position of the inverter related to the gearbox, see MGS-catalog (Impr.-No. 440 637).
The rotation of the terminal box is not possible.