2.  Installation
English
© STÖBER plc 1997
7
05.02.01
2.3.1  Mains Cable Connections
Ensure that the power source supplies the correct voltage and is designed for the necessary current. Ensure
that the appropriate circuit-breakers with the specified current rating are connected between the power supply
and CombiDrive
®
 (see section 6).
Use Class 1 60/75oC copper wire only.
Use a 4-core screened cable (for cross-section of each core see section 6). If crimp terminals are used then
they must be insulated. If crimps are not used, the strip length must not exceed 5 mm.
Feed the power cable into the inverter via the gland hole nearest to the motor shaft (see Figure 3). Connect the
power leads to terminals L1, L2, L3 and the separate earth.
Use a 4 - 5 mm cross-tip screwdriver to tighten the terminal screws.
2.3.2  Control Cable Connections
CAUTION
The control and power supply cables must be laid separately. They must not be fed through
the same cable conduit/trunking.
Use screened cable for the control lead.
Feed the control cable into the inverter via the appropriate gland hole (see Figure 3). Unplug connector block
PL800 from the PCB and connect the control wires in accordance with the information given in Figures 4a and
4b (also see Figure 3).
IMPORTANT: A wire link must be fitted between control terminals 5 (DIN1) and 8 (P15+) otherwise the
CombiDrive
®
 will not operate when control potentiometer R314 is used. The wire link must be
removed when operation via a run/stop switch is required.
Plug the connector block back into the PCB, refit the cover and tighten the four securing screws.
1
2
3
4
5
6
Power Supply
for
Analogue Input
(+10 V, max. 10 mA)
Analogue
Input
(0/2 - 10 V or
0/4 - 20 mA)
Digital
Inputs
(7.5 - 33 V, max. 5 mA)
PL800
Control Terminals
P10+
0V
AIN+
AIN-
DIN1
DIN2
9
10
11
12
Relay
(24 V dc, 1 A max.)
RL1B
(NO)
RL1C
(COM)
1
2
3
4
N (-)
P (+)
5V
(250 mA max.)
0V
SK200
Telephone Socket
(FCC 68 Type 4/4)
Power Supply
(+15 V, max. 50 mA)
For USS
Protocol
7
DIN3
8
P15+
PI-
PI+
PI +ve Input
(0 - 10 V or 0 - 20 mA)
OR
Figure 4a:  Control Terminal Connections