Datalogic Scanning DS4600A User Manual

Page of 63
DS4600A 
6 TECHNICAL 
FEATURES 
 
 
ELECTRICAL FEATURES 
DS4600A-XXX0 DS4600A0-2XX5 
Power 
 
 
Supply Voltage 
10 to 30 Vdc 
24 Vdc 
Power Consumption max. 
6 W 
12W 
Serial Interfaces 
 
Main 
RS232, RS485 full-duplex, RS485 half-duplex 
(20 mA C.L. only with C-Box 100 and INT-30 accessory ) 
Auxiliary RS232 
Baudrates 
1200 to 115200 
Inputs 
External Trigger, IN1, IN2
 
 
(optocoupled NPN or PNP) 
Voltage max. 
30 Vdc 
Input Current max. 
25 mA 
Outputs  
User-defined OUT1 and OUT2
 
 
(optocoupled open emitter, open collector) 
VCE max. 40 
Vdc 
Collector Current max.  
40 mA continuous; 130 mA pulsed 
VCE saturation 
1V at 10 mA max. 
Power Dissipation max. 
90 mW at 40 
°C (Ambient temp.) 
OPTICAL FEATURES 
 
Light Source 
Semiconductor laser diode 
Wavelength (Note 1) 
630 ~ 680 nm 
Safety Class 
Class 2 – EN60825-1; CDRH 
READING FEATURES 
(Note 2)
200X / 300X 
210X / 310X 
220X / 320X 
Aperture Angle 
66° 
70° 
60° 
Maximum Resolution 
0.25 mm 
(10 mils)
 
0.50 mm 
(20 mils)
 
0.20 mm 
(8 mils)
 
Max. Reading Distance 
See reading diagrams 
Scan Rate 
800 scans/sec 
USER INTERFACE 
 
LED Indicators 
Ready, Good Read, 
 
External Trigger , Data Transmission 
44