Bunn CDS-3 User Manual

Page of 34
14
FIG. 4  AUGER MOTOR
P1922
AUGER DRIVE MOTOR
Location:
 
The auger motor is located on the right rear of the 
motor assembly mounting panel.
Test procedures:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the positive (red wire) 
terminal and the negative (black wire) terminal on 
the auger motor with a voltmeter. With the dispenser 
door open and the product level in the CDS hopper 
lower than the probe, press and hold the SERVICE 
switch. Connect the dispenser to the power supply. 
The indication must be 4.0 to 26.5 volts dc.
 
If voltage is present as described, the auger mo-
tor drive is operating properly. If auger does not turn, 
replace the auger motor.
 
If voltage is not present as described, refer to wiring 
diagrams and check wiring harness.
Removal and Replacement:
1.  Remove hopper assembly and set aside for reas-
sembly.
2.  Remove six #8-32 screws securing the rear cover 
and remove the rear cover.
3.  Remove the four #8-32 screws located inside the 
dispenser housing on the lower right front of the 
auger motor mounting panel, securing the auger 
motor mounting bracket and auger motor to the 
rear of the auger motor mounting panel.
4  Disconnect the wires from the auger drive motor.
5.  Remove the auger motor mounting bracket, auger 
motor and dust seal as an assembly.
6.  Remove the dust seal from the auger motor and 
discard the motor.
7.  Install dust seal on the new auger motor shaft and 
align the notch in the seal with the motor casting.
8.  Connect  the  wires  from  the  auger  motor  to  the 
terminals in the main wiring harness. See Fig. 5.
9.  Using four #8-32 screws, install the auger motor, 
dust seal and mounting bracket to the rear of the 
auger motor mounting panel.
10. Install the hopper assembly.
11. Install the rear cover with six #8-32 screws.
P1902
FIG. 5 AUGER MOTOR TERMINALS
SERVICE (cont.)
RED to Control
Board (J1-1)
BLK to GRN Wire
Main Harness to
Control Board (J1-7)
29793 061599