Atmel SAM4L-EK Atmel ATSAM4L-EK ATSAM4L-EK Data Sheet

Product codes
ATSAM4L-EK
Page of 1204
843
42023E–SAM–07/2013
ATSAM4L8/L4/L2
30.10 Module Configuration
The specific configuration for each Timer/Counter instance is listed in the following tables.The
module bus clocks listed here are connected to the system bus clocks. Refer to 
 for details.
Each Timer/Counter channel can independently select an internal or external clock source for its
counter:
Table 30-4.
TC Bus Interface Clocks
Module name
Clock Name
Description
TC0
CLK_TC0
Clock for the TC0 bus interface
TC1
CLK_TC1
Clock for the TC1 bus interface
Table 30-5.
Timer/Counter Clock Connections
Module
Source
Name
Connection
TC0
Internal
TIMER_CLOCK1
Generic Clock number 5
TIMER_CLOCK2
PBA Clock / 2
TIMER_CLOCK3
PBA Clock / 8
TIMER_CLOCK4
PBA Clock / 32
TIMER_CLOCK5
PBA Clock / 128
External
XC0
PA14, PB13
XC1
PA15, PB14
XC2
PA16, PB15
TC1
Internal
TIMER_CLOCK1
Generic Clock number 8
TIMER_CLOCK2
PBA Clock / 2
TIMER_CLOCK3
PBA Clock / 8
TIMER_CLOCK4
PBA Clock / 32
TIMER_CLOCK5
PBA Clock / 128
External
XC0
PC06, PC21
XC1
PC07, PC22
XC2
PC08, PC23
Table 30-6.
Register Reset Values
Register
Reset Value
VERSION
0x00000402