b) Delay Functions
1. „Switch-Off Delay“
If the button at the input „SET“ is pushed for a short time, a positive level is pending. The relay is activated at once.
When the button at the input „SET“ is released again, the relay remains activated for the set deactivation delay T1. If the button at the input „SET“
is pushed again during this time, this does not affect the set deactivation delay (timer time T1).
The push of a button at the input „RESET“ deactivates the relay output immediately.
2. „Switch-Off Delay Resettable“
If the button at the input „SET“ is pushed for a short time, a positive level is pending. The relay is activated at once.
When the button at the input „SET“ is released again, the relay remains activated for the set deactivation delay T1. If the button at the input „SET“
is pushed again during this time, this will start the set deactivation delay T1 again.
The push of a button at the input „RESET“ deactivates the relay output immediately.
3. „Switch-On Delay“
If the button at the input „SET“ is pushed, a positive level is pending. The relay is only activated if the button is kept pushed for longer than the
activation delay time set as T1.
The relay is deactivated at once if the button at the input „SET“ is released.
The push of a button at the input „RESET“ deactivates the relay output immediately.
<-------T1------->
<-------T1------->
SET
RESET
RELAIS
SET
RESET
RELAIS
<-------T1------->
<-------T1------->
<-------T1------->
<-------T1------->
<-T1->
<-T1->
SET
RESET
RELAIS
<-------T1------->
SET
RESET
RELAIS
<-------T1------->