Peter Electronic VD 075/E2 1-phase frequency inverter, to , 2I000.23075 2I000.23075 Data Sheet
Product codes
2I000.23075
152
24
2nd deceleration ramp
0 to 2500
250 = 25.0s
153
25
Analog output function 0 to 9
See user guide for
function details
function details
154
26
Skip frequency
0 to P-01
Internal value (3000 =
50.0Hz)
50.0Hz)
155
27
Skip freq band
0 to P-01
Internal value (3000 =
50.0Hz)
50.0Hz)
156
28
V/F adjust voltage
0 to P-07
100 = 100V
157
29
V/F adjust frequency
0 to P-09
50 = 50Hz
158
30
Start mode select
0 to 6
0: Edgr-r 1: Auto_0
2…6: Auto_1 to Auto_5
2…6: Auto_1 to Auto_5
159
31
Keypad restart mode
0 to 3
See user guide for
details
details
160
32
DC injection enable
0 to 250
250= 25.0s
161
33
Spin start enable
0 or 1
162
34
Brake circuit enable
0 to 2
See user guide for
function details
function details
163
35
Analog input scaling
0 to 5000
100 = 10%
164
36
Drive address (Low
byte)
byte)
0 to 63
Drive comms address
Baudrate select
1 to 6
1 = Optibus fixed baudrate 2 = 9K6 3 = 19K2 4 = 38K4 5 = 57K6 6 = 115K2
Trip time setup
0 to 8
See user guide for more information
165
37
Access code definition
0 to 9999
166
38
Parameter lock
0 or 1
0: Unlock 1: Locked
167
39
Analog input offset
-5000 to 5000
One decimal place
300=30.0%
300=30.0%
168
40
Display scaling factor
0 to 6000
100 = 0.100
169
41
User PI P gain
1 to 300
10 = 1.0
170
42
User PI I time constant
0 to 300
10 = 1.0s
171
43
User PI mode select
0 or 1
See user guide for
more information
more information
172
44
User PI reference
select
select
0 or 1
See user guide for
more information
more information
173
45
User PI digital
reference
reference
0 to 1000
100 =10.0%
174
46
User PI feedback select 0 to 3
See user guide for
more information
more information
175
47
2nd an input format
0 to 5
0: 0...10V 1: 0…20mA
2: t 4...20mA 3: r
4...20mA 4: t 20...4mA
5: r 20...4mA
2: t 4...20mA 3: r
4...20mA 4: t 20...4mA
5: r 20...4mA