Intel E3815 FH8065301567411 Data Sheet

Product codes
FH8065301567411
Page of 5308
Intel
®
 Atom™ Processor E3800 Product Family
1126
Datasheet
28
0h
RO
MOD_STR_MON_GDC22CELLS_valid: 
Returns the value 1 if there is a command 
available on the command fifo between SP/ISP and GDC2. Returns the value 0 if the 
command FIFO for GDC2 is empty.
27
1h
RO
MOD_STR_MON_CELLS2GDC1_accept: 
Returns the value 1 if the acknowledge FIFO 
between GDC1 and ISP/SP can accept an acknowledge token from GDC1. Returns the 
value 0 if this FIFO is full.
26
0h
RO
MOD_STR_MON_CELLS2GDC1_valid: 
Returns the value 1 if GDC1 sends an 
acknowledge token using the streaming port connected to the acknowledge FIFO to the 
ISP/SP. Returns the value 0 if GDC1 does not send an acknowledge token to this FIFO.
25
1h
RO
MOD_STR_MON_GDC12CELLS_accept: 
Returns the value 1 if GDC1 can accept a 
command token from the command FIFO between the ISP/SP and GDC1. Returns the 
value 0 if GDC1 cannot accept a command token.
24
0h
RO
MOD_STR_MON_GDC12CELLS_valid: 
Returns the value 1 if there is a command 
available on the command fifo between SP/ISP and GDC1. Returns the value 0 if the 
command FIFO for GDC1 is empty.
23
1h
RO
MOD_STR_MON_SP2DMA_accept: 
Returns the value 1 if the acknowledge FIFO 
between the DMA and SP can accept an acknowledge token from the DMA. Returns the 
value 0 if this FIFO is full.
22
0h
RO
MOD_STR_MON_SP2DMA_valid: 
Returns the value 1 if DMA sends an acknowledge 
token using the streaming port connected to the acknowledge FIFO to the SP. Returns 
the value 0 if the DMA does not send an acknowledge token to this FIFO.
21
0h
RO
MOD_STR_MON_DMA2SP_accept: 
Returns the value 1 if the DMA can accept a 
command token from the command FIFO between the SP and the DMA. Returns the 
value 0 if the DMA cannot accept a command token.
20
0h
RO
MOD_STR_MON_DMA2SP_valid: 
Returns the value 1 if there is a command available 
on the command fifo between SP and the DMA. Returns the value 0 if the command 
FIFO for the DMA is empty.
19
1h
RO
MOD_STR_MON_ISP2DMA_accept: 
Returns the value 1 if the acknowledge FIFO 
between the DMA and ISP can accept an acknowledge token from the DMA. Returns the 
value 0 if this FIFO is full.
18
0h
RO
MOD_STR_MON_ISP2DMA_valid: 
Returns the value 1 if DMA sends an acknowledge 
token using the streaming port connected to the acknowledge FIFO to the ISP. Returns 
the value 0 if the DMA does not send an acknowledge token to this FIFO.
17
0h
RO
MOD_STR_MON_DMA2ISP_accept: 
Returns the value 1 if the DMA can accept a 
command token from the command FIFO between the SP and the DMA. Returns the 
value 0 if the DMA cannot accept a command token.
16
0h
RO
MOD_STR_MON_DMA2ISP_valid: 
Returns the value 1 if there is a command 
available on the command fifo between ISP and the DMA. Returns the value 0 if the 
command FIFO for the DMA is empty.
15
1h
RO
MOD_STR_MON_SP2MC_accept: 
Returns the value 1 if stream2mem can accept a 
command token from the command FIFO between the SP and the stream2mem. 
Returns the value 0 if stream2mem cannot accept a command token.
14
0h
RO
MOD_STR_MON_SP2MC_valid: 
Returns the value 1 if there is a command available 
on the command fifo between the SP and the stream2mem. Returns the value 0 if the 
command FIFO for the stream2mem is empty.
13
1h
RO
MOD_STR_MON_MC2SP_accept: 
Returns the value 1 if the acknowledge FIFO 
between the stream2mem and the SP can accept an acknowledge token from the 
stream2mem. Returns the value 0 if this FIFO is full.
12
0h
RO
MOD_STR_MON_MC2SP_valid: 
Returns the value 1 if the stream2mem sends an 
acknowledge token using its acknowledge output port connected to the acknowledge 
FIFO between the stream2mem and the SP. Returns the value 0 if the stream2mem 
does not send an acknowledge token to this FIFO.
11
0h
RO
MOD_STR_MON_SP2SIF_accept: 
Returns the value 1 if secondary input formatter 
can accept a command token from the command FIFO between the SP and the 
secondary input formatter. Returns the value 0 if this FIFO is full.
Bit 
Range
Default & 
Access
Description