Westinghouse WGR050LP076 Installation Instruction

Page of 60
45 
 
 
                                                                                  WHL-001 REV. 12.17.14 
 
1. 
Connect the outdoor sensor to the terminals marked “outdoor”. 
2.  Press
 at this screen to access the Technical Service Parameters codes (P00, P01, etc.). 
3.  Press 
 to advance through the parameters. Press 
  to return to the previous parameter. 
 
4.  Go to P06 
5.  Enter desired MIN Outdoor Temp value 
6.  Press 
 to advance to the next parameter. 
7.  To change parameter value, press 
 or  
 once. The value will appear. Press 
  to decrease or  
  to increase the 
value. 
8.  Enter desired MAX Outdoor Temp value 
9.  Press 
 to advance to the next parameter. 
10.  Enter desired MIN Storage Temp value 
11.  Press 
 to advance to the next parameter. 
12.  Enter desired MAX Storage Temp value 
13.  Press
 at this screen to accept the changed value and return to the Installer Parameters. 
 
14.  Press
 at any Installer Parameter code screens to return to the upper level menu. 
1. INQUIRY MODE AND NAVIGATION 
Inquiry Mode (
) allows the installer to access water heater operating specifics, including temperature sensor and flame sensor 
readings. These readings aid the installer in troubleshooting the water heater. 
 
To enter Installer Mode, press and hold  
 for five seconds. When the (
) screen appears, Installer Mode is active. Press 
 
once to find Inquiry Mode. The control is ready to access the Inquiry Mode when the following screen appears on the display. 
 
 
 
Press
 at this screen to access the Inquiry Mode codes (i00, i01, etc.). 
 
To view code value, press 
 or  
 once. The value will appear. Press
 at this screen to return to the code screen. 
 
Press 
 to advance through the codes. Press 
  to return to the previous code. 
 
Press
 at any Inquiry Mode code screens to return to the upper level menu. 
 
Table 12 details the Inquiry Mode codes in sequential order. 
 
CODE 
DESCRIPTION 
RANGE 
i00 
UPPER (HL NTC1) SENSOR TEMPERATURE (
o
C/
o
F) 
Between 32 and 257
o
i01 
(--*) 
--* 
i02 
Ventilation Sensor Temperature (
o
C/
o
F) 
Between 32 and 257
o
F  
i03 
Outdoor Sensor Temperature (
o
C/
o
F) 
Between 32 and 257
o
i04 
Actual Flame Current (uA x 10) 
Between 00 and 99 
i05 
Firmware Version 
Custom Version C_x.xx 
i06 
Actual Fan Speed 
 
Table 12 
– History Mode Codes – NOTE: Temperature Readings Depend on Temperature Unit Selection – *NOTE: -- Means 
option is not available or in use.
 
2. HISTORY MODE AND NAVIGATION 
History Mode (
) aids the installer in troubleshooting by allowing access to the last eight (8) error or fault codes that have occurred.