Westinghouse WGR050LP076 Installation Instruction

Page of 60
43 
 
 
                                                                                  WHL-001 REV. 12.17.14 
4. CHANGING USER SETPOINT 
Press either 
 or 
 once to change the User Setpoint. The normal operation screen will clear and be replaced by a flashing 
number. This is the User Setpoint. 
 
Press 
 to decrease or 
 to increase the setpoint. The default setpoint is 120
o
F. The setpoint range is 70 
– 160
o
F. After choosing 
the setpoint, wait five seconds. The screen will return to normal operation and the setpoint will be stored. 
 
C. ADVANCED CONTROL FUNCTIONS 
The water heater control Installer Mode includes numerous parameters for system customization. These parameters should only be 
accessed and changed by a qualified service technician. 
 
 
Installer Mode Parameters should only be accessed and changed by a qualified service technician. Failure to follow this warning could 
result in improper water heater operation, premature water heater or component failure, and/or excessively high temperatures that 
could result in scalding, property damage, severe personal injury, or death. 
 
NOTE: Water heater failures caused by improper Installer Mode Parameter sets WILL VOID product warranty. 
To enter Installer Mode, press and hold  
 for five seconds. When the following screen appears, Installer Mode is active. 
 
 
 
1. UPPER LEVEL INSTALLER MODE MENU NAVIGATION 
See Figure 24 for information on how to navigate the Installer Menu Upper Level. 
 
 
Figure 23 
– Upper Level Navigation 
2. TECHNICAL SERVICE AND NAVIGATION 
The Technical Service Menu (
) is the initial menu to appear when entering Installer Mode. Technical Service Parameters allow the 
installer to fully customize water heater settings to the system. The control is ready to access the Technical Service Parameter Menu 
when the following screen appears on the display.