Siemens Welding System ST PCS 7 User Manual
Communication
Industrial Ethernet
Passive network components: Fiber-optic cables
9/26
Siemens ST PCS 7 · November 2007
9
■
Overview
Optical transmission media
Glass fiber-optic cables are preferably used as the optical trans-
mission medium. The two types of cable offered are suitable for
above-ground routing indoors or outdoors. They are available in
fixed lengths, precut/preassembled with 2 x 2 BFOC connectors
(FIBER OPTIC standard cable) or 2 x 2 SC-connectors
(FO Standard Cable).
The FO Standard Cable with 2 x 2 SC connectors is required for
The FO Standard Cable with 2 x 2 SC connectors is required for
optical networks in the Gigabit range, e.g. for implementing op-
tical Gigabit Ethernet rings with SCALANCE X414-3E and
MM492-2 media modules.
■
Technical specifications
Switches
X414-3E + MM492-2,
X408-2 + MM492-2
X408-2 + MM492-2
X414-3E + MM491-2,
X408-2 + MM491-2,
X212-2, X212-2LD,
X202-2 IRT, X206-1LD,
X204-2, OSM
X408-2 + MM491-2,
X212-2, X212-2LD,
X202-2 IRT, X206-1LD,
X204-2, OSM
Port type
1000BaseSX
100BaseFX
Transmission rate
1000 Mbit/s
10/100 Mbit/s
Max. cable length
750 m
3000 m
Cable type
FO Standard Cable
Fiber optic standard
cable
FO multimode fiber
type
50/125 µm
62.5/125 µm
Connector type
2 x 2 SC
2 x 2 BFOC (ST)
Cable type
FO
Standard Cable
Standard Cable
FIBER OPTIC
Standard Cable
Standard Cable
Applications
Universal cable for
installation indoors and
outdoors
Delivery format
Cut-to-length,
pre-assembled with
4 BFOC(ST) or
4 SC connectors
Cut-to-length,
pre-assembled with
4 BFOC connectors
(ST)
Cable type (stan-
dard designation)
AT-W(ZN)YY
2x1G50/125
AT-VYY 2G62.5/125
3.1B200 + 0.8F600 F
Fiber type
Multimode gradient
fiber 50/125 mm
Multimode gradient
fiber 62.5/125 mm
Damping
• At 850 nm
• At 850 nm
≤
2.7 dB/km
≤
3.1 dB/km
• At 1300 nm
≤
0.7 dB/km
≤
0.8 dB/km
Modal bandwidth
• At 850 nm
• At 850 nm
≥
600 MHz
×
km
≥
200 MHz
×
km
• At 1300 nm
≥
1200 MHz
×
km
≥
600 MHz
×
km
Number of fibers
2
2
Cable design
Segmentable
Segmentable outer
conductor
Core type
Hollow core, filled
Compact core
Materials
• Basic element
PVC, orange/black
PVC, gray
• Strain relief
Aramide fiber
Kevlar fiber and impreg-
nated glass fiber
• Outer sheath/color
of cable
PVC, green
PVC, black
Mechanical charac-
teristics
teristics
• Dimensions of ba-
sic element
2.9 mm diam.
(3.5
±
0.2) mm diam.
• Cable dimensions 4.5 x 7.4 mm
(6.3
×
9.8)
±
0.4 mm
• Cable weight
Approx. 40 kg/km
Approx. 74 kg/km
• Permissible tensile
force
≤
500 N
≤
500 N (temporary)
• Bending radius
70 mm
≥
100 mm only on the
flat side
• Resistance to later-
al force
300 N/cm
–
Permissible ambi-
ent conditions
ent conditions
• Routing and instal-
lation temperature
-5 ... +50 ºC
-5 ... +50 ºC
• Operating temper-
ature
-25 ... +80 ºC
-20 ... +60 ºC
• Storage temper-
ature
-25 ... +80 ºC
-25 ... +70 ºC
Behavior in fire
–
Flame-retardant to
IEC 60332-3 and
VDE 0482-266-2-4
Silicone-free
Yes
Yes
Resistance to min-
eral oils and grease
Limited resistance
–
UL/CSA approvals
OFNG, UL1651
FT4/IEEE1202
–
UV-resistant
Yes
–
Rodent protection
–
Yes
Gigabit length
• 1000BaseSX
• 1000BaseSX
750 m
–
• 1000BaseLX
2000 m
–
© Siemens AG 2007