Siemens Welding System ST PCS 7 User Manual

Page of 344
Communication
Industrial Ethernet
Passive network components: Fiber-optic cables
9/26
Siemens ST PCS 7 · November 2007
9
Overview
Optical transmission media
Glass fiber-optic cables are preferably used as the optical trans-
mission medium. The two types of cable offered are suitable for 
above-ground routing indoors or outdoors. They are available in 
fixed lengths, precut/preassembled with 2 x 2 BFOC connectors 
(FIBER OPTIC standard cable) or 2 x 2 SC-connectors 
(FO Standard Cable).
The FO Standard Cable with 2 x 2 SC connectors is required for 
optical networks in the Gigabit range, e.g. for implementing op-
tical Gigabit Ethernet rings with SCALANCE X414-3E and 
MM492-2 media modules.
Technical specifications
Switches
X414-3E + MM492-2, 
X408-2 + MM492-2
X414-3E + MM491-2, 
X408-2 + MM491-2, 
X212-2, X212-2LD, 
X202-2 IRT, X206-1LD, 
X204-2, OSM
Port type
1000BaseSX
100BaseFX
Transmission rate
1000 Mbit/s
10/100 Mbit/s
Max. cable length
750 m
3000 m
Cable type
FO Standard Cable
Fiber optic standard 
cable
FO multimode fiber 
type
50/125 µm
62.5/125 µm
Connector type
2 x 2 SC
2 x 2 BFOC (ST)
Cable type
FO 
Standard Cable
FIBER OPTIC 
Standard Cable
Applications
Universal cable for 
installation indoors and 
outdoors
Delivery format
Cut-to-length, 
pre-assembled with 
4 BFOC(ST) or 
4 SC connectors
Cut-to-length, 
pre-assembled with 
4 BFOC connectors 
(ST)
Cable type (stan-
dard designation)
AT-W(ZN)YY 
2x1G50/125
AT-VYY 2G62.5/125 
3.1B200 + 0.8F600 F
Fiber type
Multimode gradient 
fiber 50/125 mm
Multimode gradient 
fiber 62.5/125 mm
Damping 
• At 850 nm 
 2.7 dB/km 
 3.1 dB/km
• At 1300 nm
 0.7 dB/km
 0.8 dB/km
Modal bandwidth 
• At 850 nm 
 600 MHz 
×
 km
 200 MHz 
×
 km
• At 1300 nm
 1200 MHz 
×
 km
 600 MHz 
×
 km
Number of fibers
2
2
Cable design
Segmentable
Segmentable outer 
conductor
Core type
Hollow core, filled
Compact core
Materials
• Basic element
PVC, orange/black
PVC, gray
• Strain relief
Aramide fiber
Kevlar fiber and impreg-
nated glass fiber
• Outer sheath/color 
of cable
PVC, green
PVC, black
Mechanical charac-
teristics
• Dimensions of ba-
sic element
2.9 mm diam.
(3.5 
±
 0.2) mm diam.
• Cable dimensions 4.5 x 7.4 mm
(6.3 
×
 9.8) 
±
 0.4 mm
• Cable weight
Approx. 40 kg/km
Approx. 74 kg/km
• Permissible tensile 
force
 500 N 
 500 N (temporary)
• Bending radius
70 mm
 100 mm only on the 
flat side
• Resistance to later-
al force
300 N/cm
Permissible ambi-
ent conditions
• Routing and instal-
lation temperature
-5 ... +50 ºC
-5 ... +50 ºC
• Operating temper-
ature
-25 ... +80 ºC
-20 ... +60 ºC
• Storage temper-
ature
-25 ... +80 ºC
-25 ... +70 ºC
Behavior in fire
Flame-retardant to 
IEC 60332-3 and 
VDE 0482-266-2-4
Silicone-free
Yes
Yes
Resistance to min-
eral oils and grease
Limited resistance
UL/CSA approvals
OFNG, UL1651 
FT4/IEEE1202
UV-resistant
Yes
Rodent protection
Yes
Gigabit length
• 1000BaseSX
750 m
• 1000BaseLX
2000 m
© Siemens AG 2007