Henkel LOCKTITE 97211 User Manual

Page of 60
21 
 
5    Measuring 
5.4   Storing a Reference 
   
In order to monitor dispensed quantities, reference-dispensing cycles have to be made. 
 
Only for the Automatic Controller 97103: Choose the dispensing channel in which the 
dispensing is required to be monitored. 
   
 
• To get the reference mode first press 
the button   , hold it and than press 
the button     . 
In the display the name of the dispensing 
channel changes from (B) to 
Reference. 
Now reference-dispensing can be made. 
 
 
   
• Start dispensing and inspect the quality. If o. k. store it with button    . . 
In the display the name of the dispensing channel changes from to (B) and the 
dispensing is stored as a reference. After storing, the controller switches to the normal 
dispensing mode. 
   
It is possible to store up to 10 different reference-dispensing cycles. After 10 references 
dispensing the controller stores all of them automatically and switches to the normal 
dispensing mode. Start the dispensing cycles one after the other in order of the 
requirements. 
   
If less than 10 references dispensing are required, make your quantity of reference 
dispensing. After the last required dispensing store them with button     . In the display 
the name of the dispensing channel changes from to (B) and the controller switches 
to the normal dispensing mode. 
   
All adjustments are kept stored permanently after switching off the controller. 
R
97123
ESC
QUIT
CONT
ESC
R 0.5 s 1.25 bar
* Loctite Corp.*