5    Measuring 
5.5   Monitoring 
5.5.1    Normal Monitoring Mode 
   
Every dispensing cycle, which is started, will be monitored in the order of storage. 
The quantity of the several dispensing can be different. So dispensing 0 can be different 
in quantity from dispensing 1, dispensing 1 can be different from dispensing 2 and so 
on. The order of monitoring these dispensing cycles is fixed. It will be monitored in the 
order of storage. 
For example: 
Dispensing 0   with reference 0 
Dispensing 1   with reference 1 
Dispensing 2   with reference 2 and so on. 
5.5.2    Extended Monitoring Mode 
 
This option requires knowledge of serial data communication! 
   
In this mode you can select several dispensing cycles for monitoring at your own choice. 
Therefore you have to set up the serial interface at your PC or PLC, connect this 
interface with the Loctite controller according to the pin assignment in the following and 
send a command for the reference which is required. 
   
Use the following serial I/O ports:      Dual Channel Automatic Controller 97103     XS 8
                                                            Automatic Controller 97123     XS 4
   
Be sure to follow the sequence otherwise you get no result.