Henkel LOCKTITE 97211 User Manual

Page of 60
24 
 
5    Measuring 
5.6    Software Interface for Statistic Process Control (SPC) 
   
The Flow Monitoring System offers you the possibility to get data for further process 
control. 
   
To get process data requires the connection of the flow monitoring system to a PLC or 
PC and commands to start and end the data transmittal see Section 5.5.2. 
   
The process data contains information about 
–  number of dispensing cycle respectively number of reference dispensing 
–  integral of pressure characteristic (corresponds to quantity of product dispensed), 
–  length of envelope curve for pressure characteristic, 
–  center of gravity, 
– dispensing time, 
– adjusted tolerance 
–  adjusted product pressure as a digitized value and 
–  kind of error. 
   
They can be used for quality control and have to be evaluated by the customer. 
   Start Command 
   
The start command is “D2”. The answer you get is “ok”. This means the transmittal can 
start. 
   
As long as you monitor the dispensing you get the process data. This function is 
available till you quit. It is permanently stored till you send the end command. 
   End Command 
   
To finish the transmission you have to quit using the command “D3”. The answer you 
get is “ok”. This means the transmittal is finished.