Installing the SS-100 • 1
1
Installing the SS-100
The CPC SS-100 Serial Server (P/N 570-
2000) is a device that allows Retail Solutions 
REFLECS controllers (RMCC, BEC, or 
BCU) to communicate over a TCP/IP Ethernet 
network using the controller’s serial port. Tra-
ditionally, REFLECS controllers have relied 
on a modem or a serial cable connection. With 
an SS-100 installed, the REFLECS can be in-
tegrated with a company’s existing LAN or 
WAN. 
A kit is included with the SS-100, which 
consists of:
• 5V power supply
• 9-pin (DB9) to 9-pin connector
• 9-pin to 25-pin (DB25) connector (STC)
• 10’ DB9 serial cable
• 535-1190 DB9 computer to REFLECS controller 
laptop cable (UltraSite connection only)
• DB25 null modem adapter (HALComm connection 
only)
• DB9 female/female STC gender changer (HAL-
Comm connection only)
1.1.
Working with the Network 
Administrator 
Like other computers on the network to which it is at-
tached, the SS-100 is also a network node. Because of this, 
it is important to work with the network administrator. 
Without the cooperation of the network administrator, it 
will be difficult to make the SS-100 function properly.
1.2.
IP Address Specification
An IP address and subnet mask are denoted as a series 
of four decimal numbers separated with periods. Each 
number has a value between 0 and 255. 
The following are examples of valid IP addresses and 
subnet masks. The actual numbers used as IP addresses 
must be determined by the network administrator.
 
IP Address                         192.168.1.33
 Subnet Mask                      255.255.255.0
“Empty” IP Address            0.0.0.0
1.3.
Network Considerations
Like any other node on the network, the SS-
100 must be assigned an IP address. For this rea-
son, the network administrator’s input is required 
for the SS-100 installation. Obtain the following 
information from the network administrator be-
fore configuring the SS-100.
• SS-100 IP address (required)
• Subnet mask (required)
• Primary DNS IP address (may not be re-
quired)
• Secondary DNS IP address (may not be re-
quired)
• Primary gateway IP address (may not be required)
• Secondary gateway IP address (may not be required)
1.4.
Ethernet Network Wiring and 
Wire Types
To connect the SS-100 to an existing Ethernet network, 
use the same standard Category 5 network cable used by 
the rest of the Ethernet network. If the SS-100 is being 
wired as part of a brand new network installation, consult 
your network administrator or IS technician for the proper 
wire type.
In either case, you will need to crimp an RJ45 connector 
to the end of the network cable segment that will connect to 
the SS-100.
2
SS-100 Wiring 
Requirements
Required Equipment:
• 110VAC/5VDC power transformer
• DB25/DB9 straight through connector (STC)
• 535-1190 DB9 computer to REFLECS controller 
laptop cable (UltraSite connection only)
• DB25 null modem adapter (HALComm connection 
only)
• DB9 female/female STC gender changer (HAL-
Comm connection only)
• Installation Guide
• RJ45 connection to a TCP/IP Network (not provid-