Commissioning
Code
Possible Settings
IMPORTANT
No.
Name
Default Selection
Password
225
0000 
 
9999
•  Must enter password to access 
parameters
•  P94 = 0000: Disables password
Clear Fault 
History
0
0  No Action
  Clear Fault History
Program 
Selection
0  Operate from User settings
  Operate from OEM settings
See Notes , 2 and 
2  Reset to OEM default settings See Note 
  Reset to 0 Hz default settings •  See Note 4
•  Parameters are reset to the defaults 
listed in this manual.
•  For P99=4, the following exceptions 
apply:
  - P0, P52, P, P7 = 50.0 Hz
  - P04 = 50 Hz; 
  - P05 = 450 RPM
  - P07 = 0 (480 V drives only)
4  Reset to 50 Hz default settings
5  Translate
See Note 5
WARNING!
Modification of P99 can affect drive functionality!  STOP and EXTERNAL 
FAULT circuitry may be disabled!  Check P00 and P2...P2
Note 1
If the EPM does not contain valid OEM settings, a flashing GF will be 
displayed when P99 is set to  or 2.
Note 2
When P99 is set to , the drive operates from the OEM settings stored 
in the EPM Module and no other parameters can be changed (  will be 
displayed if attempted).
Note 3
Auto Calibration is not possible when operating from OEM Settings.
Note 4
Reset 0 and Reset 50 will set the Assertion Level (P20) to “2” (High). 
P20 may need to be reset for the digital input devices being used. 
An 
 fault may occur if P20 and the Assertion switch are not set 
identically.
Note 5
If an EPM that contains data from a previous compatible software version 
is installed:
•  The drive will operate according to the previous data, but parameters 
cannot be changed (  will be displayed if attempted)
•  To update the EPM to the current software version, set P99 = 5. The 
parameters can now be changed but the EPM is incompatible with 
previous software revisions.