Delta Tau TURBO CLIPPER DRIVE User Manual
Turbo Clipper Drive User Manual
Motor Setup Guidelines
59
Flag Address, Mode Control: Ixx25, Ixx24
I125=$078000
; Motor 1 Flag Address
I225=$078008
; Motor 2 Flag Address
I325=$078010
; Motor 3 Flag Address
I425=$078018
; Motor 4 Flag Address
I124=$800401
; Motor 1 Flag Control. High True Amp Fault, disable 3
rd
Harmonic
I224=$800401
; Motor 2 Flag Control. High True Amp Fault, disable 3
rd
Harmonic
I324=$800401
; Motor 3 Flag Control. High True Amp Fault, disable 3
rd
Harmonic
I424=$800401
; Motor 4 Flag Control. High True Amp Fault, disable 3
rd
Harmonic
Commutation Address, Cycle size: Ixx83, Ixx70, Ixx71
I183=$3503
; Motor 1 on-going Commutation Address (ECT Integration Result)
I283=$3506
; Motor 2 on-going Commutation Address (ECT Integration Result)
I383=$3509
; Motor 3 on-going Commutation Address (ECT Integration Result)
I483=$350C
; Motor 4 on-going Commutation Address (ECT Integration Result)
I170,4,100=1
; Motors 1-4 Single cycle size
I171,4,100=65536
; Microsteps per Ixx70 commutation cycles