Delta Tau TURBO CLIPPER DRIVE User Manual

Page of 87
Turbo Clipper Drive User Manual 
 
Specification 
Electrical Specifications 
 
Specification 
Description 
Range 
Max ADC 
Full Range ADC reading (RMS/Axis) 
Used in I2T Calculation 
33.85 Amps 
Bus Power Supply 
Input Voltage 
12~60VDC 
Continuous  Input Current (RMS) 
12.5A 
Peak Input Current (RMS) 
25A @ 1s 
Logic Power Supply 
Input Voltage  
24VDC ±20% 
Continuous  Input Current  
2~3A  (RMS)
 
Output Current 
Nominal Current per axis (RMS) 
5A 
Maximum Peak Current per axis (RMS) 
15A @ 1s 
Power Dissipation  
240W per axis (modulation depth of 60%) 
PWM Frequency 
2K~40KHz / recommended 20KHz
 
 
Environmental Specifications 
 
Specification 
Description 
Range 
Ambient operating Temperature  
EN50178 Class 3K3 – IEC721-3-3 
Minimum operating temperature 
0°C (32°F) 
Maximum operating temperature  45°C (113°F) 
Storage Temperature Range  
EN 50178 Class 1K4 – IEC721-3-1/2 
Minimum Storage temperature 
-25°C (-13°F) 
Maximum Storage temperature 
70°C (158°F) 
Humidity Characteristics w/  
no condensation and no formation of ice 
IEC721-3-3 
Minimum Relative Humidity 
5% HU 
Maximum Relative Humidity  
up to 35°C (95°F) 
95% HU 
Maximum Relative Humidity  
from 35°C up to 50°C (122°F) 
85% HU 
De-rating for Altitude   
0~1000m (0~3300ft) 
No de-rating 
1000 ~3000m (3300~9840ft) 
-1%/m (-0.33%/ft) 
3000 ~4000m (9840~13000ft) 
-2%/m (-0.67%/ft) 
Environment 
ISA 71-04 
Degree 2 environments 
Atmospheric Pressure 
EN50178 class 2K3 
70 KPa to 106 KPa 
Shock 
Unspecified 
Vibration 
Unspecified 
Air Flow Clearances 
3" (76.2mm) above and below unit for air flow 
Cooling 
Natural convection and external fan 
Standard IP Protection 
IP20 
IP 55 can be evaluated for custom applications