Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Global I-Variables 
 160 
Note: 
These I-variables are disabled if Iyy00/50 for the motor is set to 0.  No value can 
be written to them, and if queried, they will report a value of 0. 
The following servo control I-variables are used regardless of the setting of Iyy00/50: 
Ixx59, Ixx60, Ixx68, Ixx69 
Iyy10 
– Iyy39/Iyy60 – Iyy89 
Motor xx Extended Servo Algorithm Gains 
Iyy10 through Iyy39 (for odd-numbered motors), and Iyy60 through Iyy89 (for even-numbered motors) 
are the gains for the Extended Servo Algorithm (ESA).  The following table lists the function of each 
variable; refer to the User Manual for a detailed description and diagram of the algorithm structure. 
I-Var. for 
Odd-
Numbered 
Motors 
I-Var. for 
Even-
Numbered 
Motors 
Gain 
Name 
Range 
I-Var. for 
Odd-
Numbered 
Motors 
I-Var. for 
Even-
Numbered 
Motors 
Gain 
Name 
Range 
Iyy10 
Iyy60 
s0 
-1.0
Var
+1.0 
Iyy25 
Iyy75 
TS 
-2
23
Var
2
23
 
Iyy11 
Iyy61 
s1 
-1.0
Var
+1.0 
Iyy26 
Iyy76 
L1 
-1.0
Var
+1.0 
Iyy12 
Iyy62 
f0 
-1.0
Var
+1.0 
Iyy27 
Iyy77 
L2 
-1.0
Var
+1.0 
Iyy13 
Iyy63 
f1 
-1.0
Var
+1.0 
Iyy28 
Iyy78 
L3 
-1.0
Var
+1.0 
Iyy14 
Iyy64 
h0 
-1.0
Var
+1.0 
Iyy29 
Iyy79 
k0 
-1.0
Var
+1.0 
Iyy15 
Iyy65 
h1 
-1.0
Var
+1.0 
Iyy30 
Iyy80 
k1 
-1.0
Var
+1.0 
Iyy16 
Iyy66 
r1 
-1.0
Var
+1.0 
Iyy31 
Iyy81 
k2 
-1.0
Var
+1.0 
Iyy17 
Iyy67 
r2 
-1.0
Var
+1.0 
Iyy32 
Iyy82 
k3 
-1.0
Var
+1.0 
Iyy18 
Iyy68 
r3 
-1.0
Var
+1.0 
Iyy33 
Iyy83 
KS 
-2
23
Var
2
23
 
Iyy19 
Iyy69 
r4 
-1.0
Var
+1.0 
Iyy34 
Iyy84 
d1 
-1.0
Var
+1.0 
Iyy20 
Iyy70 
t0 
-1.0
Var
+1.0 
Iyy35 
Iyy85 
d2 
-1.0
Var
+1.0 
Iyy21 
Iyy71 
t1 
-1.0
Var
+1.0 
Iyy36 
Iyy86 
g0 
-1.0
Var
+1.0 
Iyy22 
Iyy72 
t2 
-1.0
Var
+1.0 
Iyy37 
Iyy87 
g1 
-1.0
Var
+1.0 
Iyy23 
Iyy73 
t3 
-1.0
Var
+1.0 
Iyy38 
Iyy88 
g2 
-1.0
Var
+1.0 
Iyy24 
Iyy74 
t4 
-1.0
Var
+1.0 
Iyy39 
Iyy89 
GS 
-2
23
Var
2
23
 
Usually, the ESA gains that these I-variables represent are set using the Auto-tuning function of the Servo 
Evaluation Package (SEP). 
Note: 
These I-variables are disabled if Iyy00/50 for the motor is set to 0.  No value can 
be written to them, and if queried, they will report a value of 0.