M-variable definitions, P-variable values, Q-variable values, and axis definitions are not affected by this 
command.  They can be cleared by separate commands (e.g. M0..8191->*P0..8191=0
Q0..8191=0UNDEFINE ALL). 
This command is particularly useful if the program buffers have become corrupted.  It clears the buffers 
and buffer pointers so the files can be re-sent to Turbo PMAC.  Regular backup of parameters and 
programs to the disk of a host computer is strongly encouraged so this type of recovery is possible.  The 
PMAC Executive program has Save Full Turbo PMAC Configuration and Restore Full Turbo PMAC 
Configuration functions to make this process easy. 
Example: 
I130=60000 
; Set #1 proportional gain 
SAVE 
; Save to non-volatile memory 
$$$*** 
; Reset and re-initialize card 
I130 
; Request value of I130 
2000 
; Turbo PMAC reports current value, which is default 
$$$ 
; Normal reset of card 
I130 
; Request value of I130 
60000 
; Turbo PMAC reports last saved value 
See Also: 
On-line command $$$PASSWORD={string};  
Jumper E3 (PMAC2), E51 (PMAC) 
PMAC Executive Program Save/Restore Full Configuration. 
$$* 
Function: 
Read motor absolute positions 
Scope:   
Coordinate system specific 
Syntax:  
$$* 
The $$* command causes PMAC to perform a read of the absolute positions for all motors in the 
addressed coordinate system that require an absolute position read (Ixx10 > 0), as defined by Ixx10 and 
Ixx95 for the motor.  This command performs the same actions in reading the absolute position data that 
are normally performed during the board’s power-up/reset cycle if Ixx80 bit 2 is set to the default of 0. 
The action of this command is equivalent to that of a motor-specific $* command to each motor in the 
coordinate system.  Refer to the $* command description for the exact actions of this command. 
$* 
Function: 
Read motor absolute position 
Scope:   
Motor specific 
Syntax:  
$* 
The $* command causes PMAC to perform a read of the absolute position for the addressed motor, as 
defined by Ixx10 and Ixx95 for the motor.  It performs the same actions that are normally performed 
during the board’s power-up/reset cycle. 
The $* command performs the following actions on the addressed motor: 
 
The motor is killed (servo loop open, zero command, amplifier disabled). 
 
If the motor is set up for local hardware encoder position capture by input flags, with bit 0 of Ixx97 
set to 0 to specify hardware capture, and bit 18 of Ixx24 set to 0 to specify local, not MACRO, flag 
operation (these are default values), the hardware encoder counter for the same channel as the flag 
register specified by Ixx25 is set to 0 (e.g. if Ixx25 specifies flags from channel 3, then encoder 
counter 3 is cleared).