Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC On-line Command Specification 
 279 
 
The \ quick-stop command is given, which causes Turbo PMAC to come to the quickest possible 
stop in the lookahead buffer. 
 
The > resume-forward, R run, or S step command is given, which causes Turbo PMAC to resume 
normal forward execution of the program, adding to the lookahead buffer as necessary. 
 
An error condition occurs, or a non-recoverable stopping command is given. 
If any motor has been jogged away from the quick-stop point, and not returned with a J= command, 
Turbo PMAC will reject the < back-up command, reporting ERR017 if I6 is set to 1 or 3. 
This same functionality can be obtained from within a Turbo PMAC program by setting Isx21 to 7, which 
executes more quickly than CMD “&n<”
If the coordinate system is not currently in the middle of a lookahead sequence, Turbo PMAC will treat 
this command as an H feed-hold command. 
See Also: 
I-variables Isx13, Isx20, Isx21 
On-line commands \>/AHJ=RS  
Function: 
Resume Forward Execution in Lookahead Buffer 
Scope:   
Coordinate-system specific 
Syntax:  
This command causes the Turbo PMAC to resume forward execution in the lookahead buffer for the 
addressed coordinate system.  Typically, it is used to resume normal operation after a \ quick-stop 
command, or a < back-up command.  If the program is currently executing in the backward direction, it 
will be brought to a quick stop (the equivalent of the \ command) first. 
If previous forward execution had been in continuous mode (started with the R command), the > 
command will resume it in continuous mode.  If previous forward execution had been in single-step mode 
(started with the S command), the > command will resume it in single-step mode.   
The R and S commands can also be used to resume forward execution, but they may change the 
continuous/single-step mode. 
Deceleration from a backward move (if any) and acceleration in the forward direction observe the Ixx17 
acceleration limits. 
If any motor has been jogged away from the quick-stop point, and not returned with a J= command, 
Turbo PMAC will reject the > resume command, reporting ERR017 if I6 is set to 1 or 3. 
This same functionality can be obtained from within a Turbo PMAC program by setting Isx21 to 6, which 
executes more quickly than CMD “&n>”
If the coordinate system is not currently in the middle of a lookahead sequence, Turbo PMAC will treat 
this command as an R run command. 
See Also: 
I-variables Isx13, Isx20, Isx21 
On-line commands \</AHJ=RS  
Function: 
Halt Motion at End of Block 
Scope:   
Coordinate-system specific 
Syntax: