Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC On-line Command Specification 
 375 
Only one communications port of this ring controller Turbo PMAC may be in “pass-through” mode at 
any time.  The other ports are not in pass-through mode and may be used simultaneously for 
communications with the ring controller Turbo PMAC itself. 
This port is taken out of MACRO pass-through mode if it is given the <CTRL-T> command.  If another 
MACROSTASCII command is sent while the port is in pass-through mode, this command will be passed 
through and rejected by the other station, returning an ERR008. 
In pass-through mode, command errors are always reported in the form <BELL>ERRnnn<CR>
regardless of the setting of I6. 
See Also: 
On-line commands <CTRL-T>MACROMSTASCII{station #} 
MACROSTASCIIFREQ 
 
Function: 
Report value of variable controlling MACRO ring frequency 
 
Scope:   
Global 
 
Syntax:  
MACROSTASCIIFREQ 
 
 
 
MACSTAFREQ 
This command, when sent to the Turbo PMAC that is the MACRO ring controller, causes it to report the 
value of the variable that is controlling the MACRO ring frequency. Usually this variable is I6800. The 
ring frequency is inversely proportional to the setting of this value. Refer to the description of I6800 for 
details. 
MACROSTASCIIFREQ={constant} 
Function: 
Set value of variable controlling MACRO ring frequency 
Scope:   
Global 
Syntax:  
MACROSTASCIIFREQ={constant} 
 
 
MACSTAFREQ={constant} 
This command, when sent to the Turbo PMAC that is the MACRO ring controller, causes it to set the 
value of the variable that is controlling the MACRO ring frequency, both on itself, and on all devices on 
the MACRO ring, to the specified value. The ring frequency is inversely proportional to the setting of this 
value. Refer to the description of I6800 for details. 
MACROSTASCIIFREQ=* 
Function: 
Set value of variable controlling MACRO ring frequency to default 
Scope:   
Global 
Syntax:  
MACROSTASCIIFREQ=* 
 
 
 
MACSTAFREQ=* 
This command, when sent to the Turbo PMAC that is the MACRO ring controller, causes it to set the 
value of the variable that is controlling the MACRO ring frequency, both on itself, and on all devices on 
the MACRO ring, to the default value of 6527, which sets a 9.03 kHz “MaxPhase” frequency. The ring 
frequency is inversely proportional to the setting of this value. Refer to the description of I6800 for 
details.