Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Program Command Specification 
 461 
See Also: 
I-variable I5 
On-line commands ENABLE PLCDISABLE PLC<CONTROL-D>, PAUSE PLCRESUME PLC, 
LIST PLC 
Program command ENABLE PLCDISABLE PLCRESUME PLC 
PRELUDE 
Function: 
Specify automatic subroutine call function 
Type: 
Motion program 
Syntax: 
PRELUDE1{command} 
 
PRELUDE0 
where: 
 
{command} is a subprogram call from the set CALL{data}, G{data}, M{data}, 
T{data}, D{data} 
The PRELUDE1 command permits automatic insertion of a subprogram call before each subsequent 
motion command (e.g. X10Y10) or other letter-number command (e.g. L10) other than a line label in the 
motion program.  The action taken is equivalent to inserting the call into the program text before each 
subsequent motion command or letter-number command. 
The subprogram call to be performed can be specified in the PRELUDE1 command either as a CALL 
command, or as a GMT, or D code.  The value following the Call or code letter must be a constant; it 
cannot be a variable or expression.  It does not have to be an integer.  If the routine called in the subprogram 
starts with a READ statement, the motion or letter-number command itself can become arguments for the 
subprogram call.  Any motion command within a PRELUDE1 subroutine or subprogram call is executed 
directly as a motion command, without an automatic subroutine call in front of it.. 
Turbo PMAC will only execute the PRELUDE1 function if the motion or letter-number command is 
found at the beginning of a program line or immediately after the line label.  If another type of command 
occurs earlier on the program line, no PRELUDE1 function will be executed before the motion or letter-
number command.  If the command is on a line that is already in a subroutine or subprogram reached by a 
CALL or GOSUB command, no PRELUDE1 function will be executed. 
Each PRELUDE1 command supersedes the previous PRELUDE1 command.  It is not possible to nest 
automatic PRELUDE1 calls, but an automatic PRELUDE1 call can be nested within explicit subroutine 
and subprogram calls. 
PRELUDE0 disables any automatic subroutine call. 
Examples: 
PRELUDE1 CALL10 
; Insert a CALL10 before subsequent moves 
X10 Y20 
; Implicit CALL10 before this move 
X20 Y30 
; Implicit CALL10 before this move 
... 
OPEN PROG 10 CLEAR 
; Subprogram 
Z-1 
; Move down 
DWELL 500 
; Hold position 
Z1 
; Move up 
RETURN 
... 
G71 X7 Y15 P5 
; G71 calls PROG 1000 N71000 
X8 Y16 P5 
; With PRELUDE, G71 is implied (modal) 
X9 Y15 P8 
; With PRELUDE, G71 is implied (modal) 
G70 