Delta Tau GEO BRICK LV Reference Manual

Page of 760
Turbo PMAC/PMAC2 Software Reference
 
Turbo PMAC Global I-Variables 
 81 
 
I99 = $00:  32-bit addressing, no DPRAM 
 
I99 = $10:  24-bit addressing, no DPRAM 
 
I99 = $30:  16-bit addressing, no DPRAM 
 
I99 = $80:  32-bit addressing, with DPRAM 
 
I99 = $90:  24-bit addressing, with DPRAM 
 
I99 = $B0:  16-bit addressing, with DPRAM 
Actually I99 is used at power-on/reset only, so to set or change the VME bus address width, change the 
value of I99, store this new value to non-volatile flash memory with the SAVE command, and reset the 
card with the $$$ command.   
The active register into which the value of I99 is copied at power-on/reset is X:$07000F bits 0 – 7.  It is 
permissible to write to this register directly (suggested M-variable M99) to change the active setup 
without a SAVE and reset. 
Motor Setup I-Variables 
Motor Definition I-Variables 
Ixx00  Motor xx Activation Control 
Range:   
0 - 1 
Units:    
none 
Default: 
I100 = 1, I200 .. I3200 = 0 
Ixx00 determines whether Motor xx is de-activated (Ixx00 = 0) or activated (Ixx00 = 1).  If activated, 
position monitoring, servo, and trajectory calculations are performed for the motor.  An activated motor 
may be enabled – either in open or closed loop – or disabled (killed), depending on commands or events.   
If Ixx00 is 0, no calculations are performed for Motor xx, not even position monitoring, so a position 
query command would not reflect position changes.  Any Turbo PMAC motor not used in an application 
should be de-activated, so Turbo PMAC does not waste time doing calculations for that motor.  The fewer 
motors that are activated, the faster the servo-update time will be. 
Do not try to de-activate an active and enabled motor by setting Ixx00 to 0.  The motor outputs would be 
left enabled with the last command level on them. 
Ixx01  Motor xx Commutation Enable 
Range:   
0 - 3 
Units:    
none 
Default: 
Ixx01 determines whether Turbo PMAC will perform the commutation calculations for Motor xx and 
controls whether X or Y registers are accessed for the motor.  If Ixx01 is set to 0 or 2, Turbo PMAC 
performs no commutation calculations for this motor, and the single command output from the 
position/velocity-loop servo is output to the register specified by Ixx02.  If Ixx01 is 0, this register is a Y-
register; if Ixx01 is 2, this register is an X-register. 
If Ixx01 is set to 1 or 3, Turbo PMAC performs the commutation calculations for the motor, and the 
output from the position/velocity-loop servo is an input to the commutation algorithm.  Commutation 
position feedback is read from the register specified by Ixx83.  If Ixx01 is 1, this register is an X-register; 
if Ixx01 is 3, this register is a Y-register.  Typically, X-registers are used for commutation feedback 
directly on the Turbo PMAC; Typically, Y-registers are used for commutation feedback through the 
MACRO ring. 
If Ixx01 is set to 1 or 3, Ixx70 through Ixx84 must be set to perform the commutation as desired.  If Ixx82 
is set to 0, Turbo PMAC will not perform current-loop calculations, and it outputs two phase-current