Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
PinOuts and Software Setup 
 102 
Resolution Scale Factor (SF)  
Parameter 
Encoder Type 
Technique 1/3 
Technique 2 
Resolution 
Scale Factor SF 
Rotary 
[counts/rev] 
= 2
ST
 
= 2
ST-5 
= 2
ST
/32
 
Linear 
[counts/user units] 
= 1/RES 
= 1/(32*RES) 
Where  ST: 
is the rotary encoder Singleturn resolution in bits 
RES: 
is the linear scale resolution, in user units (e.g. mm) 
 
Commutation Cycle Size  
Parameter 
Motor/Encoder 
Technique 1 
Technique 2/3 
Ixx70 
Rotary 
= Number of pole pairs 
Linear 
= 1 
Ixx71 
Rotary 
= SF= 2
ST
 
if Ixx01=3 
= 2
18
 
= 262144 
= 32 * SF= 32 * 2
ST
  
if Ixx01=1 
Linear 
= ECL * SF= ECL/RES            
if Ixx01=3 
= ECL * SF / 2
Offset
 
= ECL/(RES*2
Offset
= 32 * ECL * SF  
= 32 * (ECL/RES) 
if Ixx01=1 
Where  ST: 
is the rotary encoder Singleturn resolution in bits 
RES: 
is the linear scale resolution, in user units (e.g. mm) 
ECL:  is the electrical cycle length of the linear motor, same units as RES (e.g. mm) 
 
Offset:  is the ECT commutation Offset, it is (=ST-18 for rotary, or =RES-18 for linear) 
 
SF: 
is the encoder resolution scale factor (calculated previously) 
 
 
Position and Velocity Scale Factors, Position Error Limit 
With technique 2, and technique 3 (with  encoder resolutions  greater  than 20 bits), it  is recommended to 
set the position and velocity scale factors to equal 1 and widen the position error limit. Otherwise, default 
values should be ok for all other cases. This alleviates register saturation(s), allows for higher commanded 
speed settings and easier PID (position-loop) tuning. 
    
Parameter(s) 
Technique 1 
Technique 2 
Technique 3 
Ixx08, Ixx09 
= 96 
= 1 
= 96 
= 1 
for ST < 20 
for ST ≥ 20 
Ixx67 
Default 
= 8388607 
= Default 
= 8388607 
for ST < 20 
for ST ≥ 20 
 
Absolute Power-On Position and Phasing 
Process 
Technique 1 
Technique 2 
Technique 3 
Absolute Position Read 
From serial register A, 
automatic settings 
From serial register A, 
scaling required 
From serial register A, 
automatic settings 
Absolute Phasing 
Automatic settings, 
depending on ST+MT 
From ECT for Comm., 
automatic settings 
From ECT for Comm., 
automatic settings