Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
Motor Setup 
 177 
Hall Effect Phasing: Digital quadrature encoders 
Digital  hall  sensors  can  be  used  for  rough  phasing  on  power-up  without  the  need  for  a  phasing  search 
operation such as the manual, 2-guess, or stepper phasing methods. It provides absolute information about 
where the motor is positioned with respect to its commutation cycle. It is highly desirable due to the fact 
that it allows phasing the motor without any movement. 
 
 
Note 
Inherently,  digital  hall  sensors  have  an  error  of  about  ±30°,  resulting 
in a torque  loss of about 15%. It needs to be corrected (fine phasing) 
for top operation. 
 
The Geo Brick LV supports the conventional 120° spacing  hall sensors’ type, each  nominally  with 50% 
duty  cycle,  and  nominally  1/3  cycle  apart.  The  Geo  Brick  LV  has  no  automatic  hardware  or  software 
features to work with 60° spacing. The 120° spacing format provides six distinct states per cycle: 
 
 
-60° 
0° 
60°  120°  180°  -120°  -60° 
0° 
60° 
Channel W
Channel 
V
Channel 
U
 
 
Follow these steps to implement hall sensor phasing: 
 
1.  Start with Ixx81=0, and Ixx91=0, which eventually are the parameters to be configured 
 
2.  Phase the motor manually or using the 2-guess/stepper method. 
 
3.  Jog the motor slowly (with rough PID gains), or move in open loop/by hand in the positive direction of 
the encoder while plotting Halls UVW (Mxx28) versus Phase Position (Mxx71). 
 
4.  Set up the detailed plot, scaling and processing for Halls UVW and Phase Position