Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
PinOuts and Software Setup 
 23 
PINOUTS AND SOFTWARE SETUP 
 
 
WARNING 
Installation  of  electrical  control  equipment  is  subject  to  many 
regulations including national, state, local, and industry guidelines 
and  rules.  General  recommendations  can  be  stated  but  it  is 
important  that  the  installation  be  carried  out  in  accordance  with 
all regulations pertaining to the installation. 
 
TB1: 24VDC Logic Input 
This  3-pin  Phoenix  Terminal  Block  is  used  to  bring  in  the  24-Volt  DC  supply  to  power  up  the  logic 
portion of the Geo Brick LV. This power can remain on regardless of the main DC bus power, allowing 
the signal electronics to be active while the main motor power control may be passive. 
The 24Volts power supply must be capable of providing 2~4Amps per Geo Brick LV. If multiple drives 
are  sharing  the  same  24-Volt  power  supply,  it  is  highly  recommended  to  wire  each  drive  back  to  the 
power supply terminals separately. 
This connection can be made using a 22 AWG wire directly from a protected power supply. 
 
Pin # 
Symbol 
Function 
Description 
Notes 
+24VDC 
Input 
Logic power input + 
+16~32VDC 
CHGND 
Ground 
Chassis ground 
Connect to Protection Earth 
+24VDC RET 
Common 
Logic power return - 
Connect to Power Supply Return  
 
Phoenix Contact mating connector part# 1735879 
Delta Tau mating connector part# 016-090A03-08P 
1
2
3
 
 
 
 
24 VDC 
Power Supply
+24VDC
COM