Delta Tau GEO BRICK LV User Manual

Page of 271
Geo Brick LV User Manual
 
Troubleshooting 
 252 
ADC A Status Word 
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Bit #
Status Bits
Reserved
=0 Servo
=1 Stepper
ADC A Current Value
 
Bits [8:6] (hex) 
Error Code 
000 ($0) 
No error, Not ready 
001 ($1) 
No error, Ready 
010 ($2) 
Bus Under-Voltage Warning 
011 ($3) 
Over-Temperature ( > 70°C) 
100 ($4) 
Over Voltage ( > 85 VDC) 
101 ($5) 
I2T Warning/Fault 
110 ($6) 
Over-Current Fault 
 
 
Note 
These status bits can be useful for custom-written graphic user 
interface allowing the display of faults to the operator. 
 
ADC B Status Word 
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
Bit #
Reserved
ADC B Current Value
Amplifier Firmware 
Version Code
Axis Current Option
 
If bits [11:10] of the Strobe Word are = 11 then ADC B bits [9:6] display the amplifier firmware version. 
If bits [11:10] of the Strobe Word are = 00 then ADC B bits [7:6] display the axis current option: 
 
Bits [7:6]  Current Option 
00 
5A / 15A 
01 
1A / 3A 
10 
11 
0.25A / 0.75A