Whirlpool T-K1S User Manual

Page of 26
 
1
Table of Contents 
 
Specifications……………………………..  
For Your Safety…………………………...  
Operation………………………………….  
 General…………………………… 3 
 
Turning It On……………………… 
 
Turning It Off……………………… 
 Temperature……………………… 3 
 Flow……………………………….. 3-4 
 Freeze 
Protection………………... 4 
Installation…………………………………  
 General…………………………… 5 
 Accessories………………………. 5 
 Electrical 
Connections…………... 5 
 
Wiring diagram ………………..      
 
Gas Supply Piping………………. 
 Water 
Plumbing………………….. 8 
 Pressure 
Relief 
Valve……………. 8 
 
Wall Hanging Installation………... 
 Standing 
Installation……………... 9 
 Outdoor 
Installation……………… 9-10 
 Indoor 
Installation………………... 10-11 
  Combustible 
Air 
Supply…. 
10 
  Exhaust 
Venting…………. 
11 
Manufactured Home (Mobile Home) 
Installation……………….………... 11 
 Indoor……………………… 
11 
 Outdoor……………………. 
11 
Initiating the Appliance…………... 
12 
Initial Operation…………………... 
12 
Space Heating Application……….. 
13 
Dual Purpose Heating……………. 
14 
Applications………………………. 15 
  Storage 
Tank……………... 
15 
  Recirculation……………… 
15 
Before Operating………………….. 
16 
Danger……………………………… 17 
Maintenance………………………………  
18 
Troubleshooting…………………………..     
18-19 
Optional Items…………………………….  
20 
 TK-RE01………………………….. 20 
 TK-BK01………………………….. 20 
 TK-TV01…………………………... 20 
 TK-TV03…………………………... 20 
 TK-TV04…………………………… 
20 
Parts Diagram ……………………………       
21-22 
Parts List ………………………………..    
23 
Flow Chart………………………………..   
24 
 
 
 
 
 
 
 
 
 
Specifications 
 
Natural Gas Input 
Min. 15,000 Btu 
 
Max. 190,000 Btu 
 
LPG Input 
Min. 17,000 Btu 
 
Max. 190,000 Btu 
 
Gas Connection 
¾” NPT 
 
Water Connections 
¾” NPT 
 
Water Pressure 
Min. 15 psi 
 
Max. 150 psi 
 
Natural Gas Pressure Inlet  Min. 5” WC 
 Max. 
10.5” 
WC 
 
LP Gas Pressure Inlet 
Min. 11” WC 
 
Max. 14” WC 
 
Manifold Pressure 
Natural 2.9” WC  
 
Propane 3.5” WC  
 
Weight 45 
lbs. 
 
Dimensions 
24” x 16.5” x 8” 
 
Ignition Electronic 
Ignition 
 
Electrical Supply 
AC 120 V 
 
*** 
 
• Inlet gas pressure must not exceed the 
above maximum values. 
•  For gas pressures lower than 5” WC for 
natural gas, call the manufacturer. 
•  Before installing in areas over 4,500 feet 
above sea level, contact the manufacturer 
for high altitude adjustment instructions. 
•  Check the rating plate to insure this 
product matches your specifications. 
•  Takagi - USA is constantly improving our 
products therefore specifications are 
subject to change without prior notice.