loading must be considered. Also, do not rest any unsupported equipment on a rack-
mounted 
iPump 562
 unit.
Circuit Overloading
Consideration should be given to the connection of the equipment to the supply circuit and 
the effect that overloading of circuits could have on overcurrent protection and supply 
wiring. Ensure that the total rack or breaker power consumption does not exceed the limits 
of the AC branch circuit. Appropriate consideration of equipment ratings should be used 
when addressing this concern.
Reliable Earthing
When connecting the 
iPump 562
 unit to the power supply, review the ratings of all 
equipment in the circuit to ensure that the branch circuit, as well as the power source, will 
not be overloaded. Also make sure that the unit is properly grounded and/or that a protected 
power strip is used to attach it to the power supply
Rack Mounting
The 
iPump 562
 unit should be installed in such a way that a half-inch clearance is allowed 
on each side and a quarter-inch on the top to ensure adequate air flow. Ensure that a 
hazardous condition is not produced by uneven loading, or by resting any unsupported 
equipment on a rack-mounted 
iPump 562
 unit.
Parts for the 
iPump 562
 unit include 2 angle rack mount brackets and 4 rubber feet. For rack 
mounting, do not attach the rubber feet as they interfere with the rack mounting. 
1. Remove the 2 screws from the left and right sides of the unit. 
2. Insert the angle brackets into the left and right sides of the unit ensuring that the 
screw holes for the unit and brackets are aligned.
3. Secure the brackets by re-inserting the screws through the brackets and unit.
4. Install the unit onto the rack.
Note:  The front brackets must be secured to the rack. If the front brackets are left 
unsecured, the unit may shift forward and fall from the rack, and may result in 
personal injury and/or damage to the equipment. The internal temperature of the 
rack should not exceed 40
o
 C.
Desktop Installation
Parts for the 
iPump 562
 unit include 2 angle rack mount brackets and 4 rubber feet. For 
desktop installation, do not attach the brackets.
1. Attach the 4 rubber feet onto the indented areas at the bottom of the unit.
2. Place the unit on a flat surface where it will not be subject to spills or impacts.
3. Route cables to the unit so that they will not be hit or pulled, causing damage to the 
connectors or to the unit itself. Ensure a sufficient flow of cool air so that the unit's 
operating ambient temperature range is not exceeded.