Thermador PH30HS Installation Instruction

Page of 48
English 4
Appliance Installation
CAUTION:
Vent unit to the outside of building only.
The hood can be mounted on a wall or suspended from a 
cabinet. Both vertical and horizontal discharge are possible 
with either mounting method.
Discharge Direction:
The hood is shipped ready for vertical discharge. To 
change to horizontal discharge, move the discharge cover 
shown in Figure 1 to the top of the hood. The plate is held 
in place by four (4) screws.
Assembly of the Transition:
The supplied transition mounts to the top or rear of the 
hood depending on the discharge direction.
1. Align mounting holes at base of transition with 
mounting holes on 1/2” flange located at the top or rear 
of the hood, depending on direction of discharge.
2. Fasten transition to hood using two (2) # 8 sheet metal 
screws (included with hood).
3. Seal connection between transition and hood with duct 
tape.
4. Remove tape holding damper closed.
See Figure 2 for overall hood dimensions.
* Varies by model.
Note:
Read Remote Control Installation Instructions before 
continuing if using this accessory.
 Figure 1:  Discharge Direction
This opening 
is covered for 
horizontal 
discharge
This opening 
is covered 
for vertical 
discharge
 Figure 2: Overall Dimensions
30", 36", 42", 48", 54"*
18"
24", 27"*