                        OPERATION 
 
 
            MAIN BURNER ADJUSTMENTS
 
 
 
All Salamanders are provided with a fixed burner orifice to provide 10,500 
BTU/HR per burner at the “MAX” setting for NATURAL gas supplied at 5.0” 
W/C pressure and 10,500 BTU/HR per burner at the “MAX” setting on 
PROPANE gas supplied at 10.0” W/C pressure. 
 
 
The “LOW” setting is adjustable and should be set as follows:  
   
1.  Set the burner valve knob to the low setting and remove the burner knob. 
2.  Insert a thin bladed screwdriver into the valve stem to engage the slot inside 
the stem. 
3.  Holding the valve stem turn the setscrew clockwise to decrease the rate and 
counter clockwise to increase rate. 
4.   Proper adjustment is attained at a point where the burner flame travels back 
and forth across the face of the ceramics. (If set too low a constant spark 
will be continuous. If this occurs increase the low setting.) 
 
This adjustment has been factory pre-set, however, with changing pressures this 
adjustment may need to be re-done after installation. 
 
 
THIS IS NOT CONSIDRED A MANUFACTURING DEFECT AND IS    
NOT WARRANTABLE 
          
 
 
 
 
 
 
 
 
 
 WARNING NEVER cover any slots, holes or passages in the oven bottom or 
cover an entire rack with materials such as aluminum foil. Doing so blocks airflow through 
the oven and may cause carbon monoxide poisoning.  Aluminum foil linings may also trap 
heat, causing a fire hazard. 
 
 
 
 
 
 
 
 
 
 
      