Perlick HA24BB31L Use & Care Manual

Page of 22
PERLICK RESIDENTIAL INSTALLATION MANUAL
4
perlick.com
OPERATION
MASTER SWITCH
Signature Series products come equipped with a master power 
switch located behind the louvered toe kick. Remove the toe 
kick to turn power on or off to the unit.
INTERIOR LIGHT
Door units are equipped with an interior light that illuminate 
when the door is opened. All HP24 and HH24 models come 
standard with adjustable blue and white LED lighting. HC and 
HA come with a specialty appliance light located on back 
wall or ceiling depending on the model. The cabinet also 
comes equipped with a manual light switch for displaying the 
products through a glass door. 
Always ensure that the manual light switch is  in the OFF 
position before closing a solid wood or stainless steel door. 
If manual light switch is left on for an extended period of 
time, it may increase the cabinet temperature, and cause the 
refrigeration system to run harder. 
Perlick Signature Series, C-Series and ADA Compliant freezer 
units come standard with state-of-the-art digital control. Please 
note there are three sets of instructions; one for 24” Signature 
Series Dual-Zone models, one for C-Series, and another set for 
15”, 24” Single-Zone and Sottile, and 48” Signature Series and 
ADA-Compliant Freezer models.
Programming Button Definitions:
SET button
DEFROST button (melting snowflake)
UP arrow
DOWN arrow
ON/OFF button 
Signature Series Dual-Zone  Control Instructions
Upper Compartment:
To view the upper compartment temperature, press and release 
the DEFROST button (melting snowflake).
Lower Compartment (Must be coldest zone):
Display reading always shows the lower compartment 
temperature.
Setpoint Display:
Press and release the SET button; display will read St1. Press SET 
again and the LOWER compartment setpoint will be displayed.
Press SET again; the display will read St2. Press SET again and 
the UPPER compartment temperature will be  displayed.
Changing the Lower Compartment Temperature:
1. Press and hold the SET button until the display shows St1 
with”F” flashing.
2. Press SET again to display the upper compartment’s current 
temperature (“F” will continue to flash).
3. Use the UP or DOWN arrow key to scroll to the desired 
temperature. The controller will memorize the new 
temperature. 
Changing the Upper Compartment Temperature:
1. Press and hold the SET button until the display shows St1 
with”F” flashing. Press the DOWN arrow once; the display will 
read St2,
2. Press SET again to display the upper compartment’s current 
temperature (“F” will continue to flash).
3. Use the UP or DOWN arrow key to scroll to the desired 
temperature. The controller will memorize the new 
temperature. 
LOADING PRODUCT
Before storing perishables, turn unit on and allow it to operate 
for a minimum of 24 hours to allow temperatures to stabilize. 
When loading items into the unit, do not block internal louvers 
and fan guard openings or performance will be decreased.
CHECKING PRODUCT TEMPERATURE
1). To accurately check the temperature of product stored in the 
refrigerated compartment, insert an accurate thermometer into 
a plastic unbreakable bottle, partially filled with water. Tighten 
bottle cap securely.
2). Place the bottle in the desired area for 24 hours. Refrain from 
opening the unit during the testing period. After 24 hours, 
check the temperature of the water. Adjust the temperature 
accordingly using the following procedures:
DIGITAL TEMPERATURE CONTROL
Signature Series Models
Figure 1.  Digital Temperature Controller