Perlick HA24BB31L Use & Care Manual

Page of 22
PERLICK RESIDENTIAL INSTALLATION MANUAL
6
perlick.com
LED Functions
The following table describes LED Funtions
DIGITAL TEMPERATURE CONTROL
C-Series Models
Figure 2.  nEW 961 Digital Temperature Controller
To  Change Setpoint Temperature 
1. Press  
 . “SP” will be displayed. Press 
 again to display 
current setpoint temperature.
2. Press 
 and    to modify it and  
 or   to save the 
change.
On/Off
To turn the unit off, press and hold     for at least 5 seconds. 
“OF” will be displayed. To turn the unit on again, press and hold  
  for at least 5 seconds.
Perlick C-Series units come standard with digital control.
Programming Button Definitions:
Defrost LED
Permanently on: defrost active
Flashing: manual defrost active
Off: otherwise
Alarm LED
Permanently on: alarm active
Flashing: alarm acknowledged
Off: otherwise
Evaporator LED
Permanently on: fans active
Off: otherwise
Compressor LED
Permanently on: compressor active
Flashing: a delay, a protection or a 
locked start-up
Off: otherwise
Aux LED
Permanently on: Aux output 
active
Off: otherwise
°C LED
Permanently on: display the 
temperature
Off: otherwise
 
 STAND-BY (ESC)
Press and release
•  Returns to the previous 
menu level
•  Confirms parameter value
Press for at least 5 sec.
•  Activates the Standby 
function (off ) (When 
outside the menus)
 
 SET (ENTER)
Press and release
•  Opens Machine Status menu 
and displays alarms (if active)
Press for at least 5 sec.
•  Opens Programming menu
•  Confirm commands
 UP
Press and release
•  Scroll menu items
•  Increases values
Press for at least 5 sec.
•  Activates the Manual 
Defrost function
 DOWN
Press and release
•  Scroll menu items
•  Decreases values
Press for at least 5 sec.
•  Function can be configured 
by the user   
 
NOTE: Dependent on the model and configuration, the controllers 
have been programmed to only allow a temperature adjustment 
within a specified range. See the chart below for the specified range 
allowed for your unit.
NOTE: When switched on, the device performs a Lamp Test; the 
display and LEDs will flash for several seconds to check that they all 
function correctly.
C-Series Models
Model
Temp Range
HC24R
33° - 42° F
HA24BB
33° - 48° F
HA24WB
45° - 65° F
 
DIAL TEMPERATURE CONTROL
ADA-Compliant Models
(Excludes ADA Freezer - HA24F models use digital controller found 
on page 5)
 
C
O
O
LE
R
OFF
1
2
3
4
5
6
COLD
Figure 3.  Dial Temperature Controller
Use a straight slot screwdriver to adjust the dial temperature 
control. The control is located at the top rear panel of the 
cabinet. Approximate temperature ranges are as follows:
ADA-Compliant Series
Model
Temp Range
HA24RB
33° - 42° F
HA24BB
35° - 48° F
HA24WB