Marvel 15" Built-In Ice Maker - Black Cabinet & Overlay Door User Manual

Page of 56
DIMENSIONS FOR  30IMAT SOLID OVERLAY DOOR
13
* Depth dimension may vary depending on
   each individual installation.
Electrical Requirements: A grounded 115 volt, 15 
amp dedicated circuit is  required.
Power outlet can be located in the back wall behind 
the ice machine. Add 1” to depth for thickness of 
plug, or recess outlet 1” into the wall. Power outlet 
can also be installed in adjacent cabinetry with a 
cutout for routing of power cord. Follow all local 
building codes when installing electrical and the ice 
machine.
Product weight = 100 lbs. (45.5 kg.)
** Minimum rough in opening required is to be
      larger than the adjusted height of the cabinet.
15” (38.1 cm)
*24” (61 cm)
standard cabinet 
depth
** 313/8” to 323/8”
(79.7 to 82.2cm)
ROUGH IN OPENING DIMENSIONS, FOR 30IMAT SOLID OVERLAY DOOR
8” (20.3cm)
CL gravity
drain
371/16”
(95.4cm)
227/8”*
(58.1cm)
211/2”
(54.6cm)
3” to 4”
(7.6 to 8.8cm)
311/8” to 321/8”
(79.1 to 81.6cm)
* To face of door with-
out custom panel
137/8”
(35.3cm)
CL water supply
6” (15.2cm)
2” (5.1cm)
147/8”
(37.8cm)
CL water supply
2” (5.1cm)