Mitsubishi Electronics Q172HCPU User Manual

Page of 454
 
 
 
3 - 60 
3   POSITIONING DEDICATED SIGNALS 
 
3.5 Special Registers (SP.D) 
There are 256 special register points of D9000 to D9255 in the Motion CPU. 
Of these, 23 points of the D9112 and D9180 to D9201 are used for the positioning 
control. 
The special registers used for positioning are shown below. (Refer to APPENDIX 2.2 
"Special registers" for the applications of special registers except D9112 and D9180 to 
D9201.) 
 
Table 3.3 Special register list 
Device No. 
Signal name 
Refresh cycle 
Fetch cycle 
Signal direction 
D9112 
Connect/disconnect 
Main cycle 
Main cycle 
Command device/
Monitor device 
D9180 
D9181 
Unusable 
 
 
 
D9182 
D9183 
Test mode request error information 
At test mode request 
D9184 
Motion CPU WDT error cause 
At Motion CPU WDT error 
occurrence 
D9185 
D9186 
D9187 
Manual pulse generator axis setting error 
information 
At the manual pulse generator 
enable flag   
D9188 
Motion operation cycle 
Operation cycle 
D9189 
Error program No. 
D9190 
Error item information 
At start 
D9191 
D9192 
Servo amplifier loading information 
At power supply on/ 
operation cycle 
D9193 
D9194 
D9195 
Real/virtual mode switching error 
information (SV22) 
At virtual mode transition 
D9196 
PC link communication error codes 
Operation cycle 
D9197 
Operation cycle of the Motion CPU setting 
At power supply on 
 
Monitor device 
D9198 
D9199 
Unusable 
 
 
 
D9200 
State of switch 
Main cycle 
D9201 
State of LED 
Immediate 
 
Monitor device